UPS systems

SL line-interactive UPS

Pure sine-wave line-interactive UPS with LCD for computers, small offices and network equipment. 1–5 kVA.

Request a quote
SL line-interactive UPS

Overview

Division
UPS systems
Product line
Line-interactive UPS
Rating
1–5 kVA
Published models
8
Open in company profile

The SL series is a line-interactive UPS with pure sine-wave output and an LCD, from 1000 VA to 5000 VA. Standard models carry internal sealed maintenance-free lead-acid batteries; long-backup (L) models connect to an external battery bank of the user's choice and charge it at an adjustable 3–20 A.

  • Pure sine-wave output
  • LCD display
  • Wide input voltage range, 145–275 VAC
  • Typical 2–6 ms transfer time
  • Auto restart when AC recovers
  • Charges even when the UPS is off
  • Battery low-voltage protection
  • Overload, short-circuit and over-current protection
  • Pre-installed USB management

Applications

Personal computers and workstationsSmall offices and shopsNetwork and security equipment
ModelRatingDC voltageBatteryDimensionsNet weightCharging current
SL-1K1000 VA / 800 W24 V2×12V-7Ah (internal)384×122×192 mm9.7 kg—
SL-2K2000 VA / 1600 W24 V4×12V-7Ah (internal)375×192×330 mm22.5 kg—
SL-3K3000 VA / 2400 W48 V4×12V-9Ah (internal)375×192×330 mm24.5 kg—
SL-5K5000 VA / 4000 W48 V4×12V-17Ah (internal)585×192×330 mm48 kg—
SL-1KL1000 VA / 800 W24 VExternal384×122×192 mm8.5 kg3–20 A adjustable
SL-2KL2000 VA / 1600 W24 VExternal455×195×330 mm15 kg3–20 A adjustable
SL-3KL3000 VA / 2400 W48 VExternal455×195×330 mm19.5 kg3–20 A adjustable
SL-5KL5000 VA / 4000 W48 VExternal455×195×330 mm26 kg3–20 A adjustable

Specifications

Common to all models in the series. Specifications are subject to change without notice.

Download datasheet

Input (AC mode)

Nominal input voltage
220 VAC
Input voltage range
145–275 VAC
Input frequency
45–65 Hz

Output (inverter mode)

Output voltage
220 VAC ±5%
Output frequency
50 ±0.5 Hz / 60 ±0.5 Hz (auto sensing)
Power factor
0.8
Waveform
Pure sine wave
Transfer time
Typical 2–6 ms, max. 10 ms
Overload
110%: shuts down after 60 s · 120%: shuts down after 5 s
Over-current protection
Shuts down within 20 ms

Battery

Battery type
Sealed maintenance-free lead-acid
Charging period
Standard models: 6–8 h to 90%; L models: depends on the batteries connected

Protection & interface

Protections
Auto restart, offline charging, battery low-voltage, overload, short-circuit and over-current protection (breaker in AC mode)
Display
LCD
USB management
Pre-installed

Specifying SL line-interactive UPS?

Share the load, site conditions and timeline, and our team will confirm the right model.

Discuss a requirement