UPS systems

MP1100 1/1 phase online UPS

Transformer-based single-phase double-conversion online UPS for telecom, banking, industry and medical loads. 1–30 kVA.

Request a quote
MP1100 1/1 phase online UPS

Overview

Division
UPS systems
Product line
Online UPS
Rating
1–30 kVA
Published models
10
Open in company profile

MP1100 is a new generation of transformer-based true online double-conversion UPS with full digital control. A high-speed microprocessor (MCU) and a programmable logic device (CPLD) run the control software, with sixth-generation low-loss, high-power IGBTs and a static switch as the power components, to meet the availability and power-quality needs of a wide range of critical applications.

  • Low-frequency true online double-conversion technology
  • LED + LCD display, operated from the LCD panel
  • IGBT PWM inverter, efficiency up to 92%
  • Wide input voltage range
  • Intelligent battery management extends battery life
  • 0–100% load step without switching to bypass
  • Static bypass and manual maintenance bypass
  • 256-event real-time log
  • Selectable UPS, ECO or inverter mode
  • Generator compatible, auto restart
  • RS232 & RS485 standard; dry contacts or SNMP card optional
  • Optional EPO and battery detecting module

Applications

Telecom and bankingSecurity and transportUtilities and manufacturingCommerce and governmentMedical equipment
ModelRatingBattery voltageDimensions (W×D×H)WeightNoise
MP1101K1 kVA / 0.8 kW48 VDC210×520×530 mm42 kg45–50 dB
MP1102K2 kVA / 1.6 kW48 VDC210×520×530 mm52 kg45–50 dB
MP1103K3 kVA / 2.4 kW48 VDC210×520×530 mm59 kg45–50 dB
MP1104K4 kVA / 3.2 kW192 VDC220×520×640 mm59 kg50–55 dB
MP1106K6 kVA / 4.8 kW192 VDC220×520×640 mm65 kg50–55 dB
MP1108K8 kVA / 6.4 kW192 VDC220×500×760 mm84 kg55–60 dB
MP1110K10 kVA / 8 kW192 VDC220×500×760 mm92 kg55–60 dB
MP1115K15 kVA / 12 kW192 VDC450×600×1200 mm186 kg55–60 dB
MP1120K20 kVA / 16 kW192 VDC450×600×1200 mm201 kg55–60 dB
MP1130K30 kVA / 24 kW192 VDC450×600×1200 mm251 kg55–60 dB

Specifications

Common to all models in the series. Specifications are subject to change without notice.

Download datasheet

Rectifier (input)

Working principle
Low-frequency transformer-based true online double conversion
Phase
Single phase
Input power factor
≥0.9 (plus filter)
Input voltage range
220 VAC (230 or 240 VAC) ±25%, 1P+N+PE; optional 110 V (120 or 277 V)
Input frequency range
50 Hz ±10% / 60 Hz ±10% (selectable)
Output ripple
<2%
Soft start
0–100% in 5 s

Charging & battery

Charging mode
Constant current, then constant voltage, with temperature compensation
Float charging voltage
55 VDC (1–3 kVA); 220 VDC (4–30 kVA)
Equalised charging voltage
56.8 VDC (1–3 kVA); 227 VDC (4–30 kVA)
Temperature-compensated voltage
−3 mV/°C/cell
Charging current
5–10 A
Battery type
VRLA / AGM / Gel, optional lithium
Battery capacity
7–999 Ah settable (to suit back-up time)
Quantity
4×12 V or 24×2 V (48 VDC); 16×12 V or 96×2 V (192 VDC)

Inverter (output)

Phase
Single phase
Nominal voltage
220 VAC (230 or 240 VAC), 1P+N; optional 110 V (120 or 277 V)
Voltage regulation
±1% (stable load), ±3% (fluctuating load)
Output frequency
50 / 60 Hz <±0.5% (asynchronous)
Crest factor
>3:1
THD
Pure sine wave; linear load <3%, non-linear load <5%
Dynamic response
<±5% (0–100% load), recovery <10 ms
Overload capacity
115% continuous · 125% 10 min · 150% 1 min · 200% 1 s
Inverter efficiency
>92% (full load)

Bypass & protection

Bypass
Single phase (P+N), 220 VAC (230 or 240 VAC); optional 110 V
Transfer time
0 ms (static switch)
Input protection
Input voltage and frequency over-limit
Output protection
Over-current, short circuit, over-voltage, low voltage
Battery protection
Over-charge, over-discharge
Temperature protection
Environment and inverter over-temperature
Hardware fault protection
Auxiliary power, breaker, power device over-current / over-voltage, etc.

General

Working environment
−10–40 °C, 30–90% RH, <2000 m (1% derating per 100 m, max. 4000 m)
Cooling
Forced ventilation
Communication
RS232 / RS485, optional dry contact, SNMP card
Parallel operation
Tandem hot backup
Anti-surge capacity
10/700 µs 5 kV; 8/20 µs 20 kA
Protection level
IP21
Safety
Vin-n Vout-n 2000 Vac, leakage <10 mA, insulation >2 MΩ (500 VDC)
Voltage versions
100–110–120 V version available

Specifying MP1100 1/1 phase online UPS?

Share the load, site conditions and timeline, and our team will confirm the right model.

Discuss a requirement
WhatsAppGet help