Solar energy

BKS-PV9000OD-48L IP66 hybrid inverter

6 kW single-phase hybrid inverter in an IP66 outdoor enclosure, with two MPP trackers for up to 9 kW of PV. 6 kW.

Request a quote
IP65 hybrid solar inverter

Overview

Division
Solar energy
Product line
Solar inverters
Rating
6 kW
Published models
1
Open in company profile

A 6 kW single-phase hybrid inverter in an IP66 outdoor enclosure. It takes up to 9 kW of PV on two MPP trackers, exports 6 kW to the grid, carries 6 kW of backup load with a switch time under 20 ms, and charges 48 V lithium or lead-acid batteries at up to 120 A. Solar, grid, generator, smart loads and battery all connect through the one inverter, monitored over Wi-Fi.

  • Wide MPPT range, 80–520 V
  • 2 MPP trackers, 19 A input current per string
  • Type III surge protection on both DC and AC side
  • IP66 protection, natural cooling
  • Backup switch time under 20 ms
  • Lithium and lead-acid batteries, up to 120 A charge / discharge
  • Wi-Fi monitoring as standard; GPRS or 4G optional

Applications

Residential solar with battery storageGrid-tied self-consumption with backupGenerator-assisted sites
ModelRating
BKS-PV9000OD-48L6 kW · 48 V

Specifications

Common to all models in the series. Specifications are subject to change without notice.

Download datasheet

PV input

Max. PV input power
9 kW
Max. PV open-circuit voltage
550 V
MPPT operating range
80–520 VDC
Full-power MPPT range
250–500 VDC
Start-up voltage
90 VDC
Max. input current per MPPT
19 / 19 A
Max. short-circuit current
25 / 25 A
MPPT trackers / strings
2 / 1
Nominal input voltage
360 V

AC output (on-grid)

Nominal output power to grid
6 kW
Max. apparent power to / from grid
6 kVA / 6 kVA
Max. current from grid
26.1 A
Nominal output current
26.1 A
Max. output current to grid
26.1 A
Nominal voltage / frequency
230 V (176–280 V), 50/60 Hz, L+N+PE
Adjustable power factor
0.8 leading – 0.8 lagging
THDi
<2%

AC output (backup)

Nominal output power
6 kW
Max. apparent power
6 kVA
Nominal / max. output current
26.1 A / 26.1 A
Nominal voltage / frequency
230 V (176–238 V), 50/60 Hz, L+N+PE
Automatic switch time
<20 ms
THDu
<2%
Overload capacity
110% 30 s · 120% 10 s · 150% 0.02 s

Efficiency

Max. efficiency
98.0%
MPPT efficiency
99.0%
Max. battery charge / discharge efficiency
94.6%

Battery

Voltage range
40–60 V
Recommended battery voltage
48 V
Max. charging voltage
60 V
Max. charging / discharging current
120 / 120 A
Battery type
Lithium and lead-acid

Protection

DC switch
Yes
DC reverse-polarity protection
Yes
DC / AC surge protection
Type III / Type III
AC overvoltage and short-circuit protection
Yes
Ground-fault, residual-current and insulation monitoring
Yes
Anti-islanding protection
Yes
Peak / valley time setting
Yes

General

HMI
LCD & app
BMS
RS485; CAN
EMS / meter
RS485
Communication
Wi-Fi (standard) / GPRS / 4G (optional)
Ingress protection
IP66
Operating temperature
−25–60 °C
Relative humidity
0–95% (non-condensing)
Max. altitude
4000 m (derating above 3000 m)
Cooling
Natural
Noise
≤29 dB
Dimensions (W×H×D)
485×527×230 mm
Net weight
24 kg
Self-consumption
<10 W
Safety / EMC
IEC/EN 62109-1/-2 · IEC/EN 61000-6-1/-2/-3

Specifying BKS-PV9000OD-48L IP66 hybrid inverter?

Share the load, site conditions and timeline, and our team will confirm the right model.

Discuss a requirement
WhatsAppGet help