Solar energy

BKS series hybrid solar inverter

Single-phase hybrid solar inverters with a built-in MPPT charger, dual AC output and Wi-Fi monitoring. 3–5 kVA.

Request a quote
IP21 hybrid solar inverter

Overview

Division
Solar energy
Product line
Solar inverters
Rating
3–5 kVA
Published models
2
Open in company profile

Two hybrid solar inverters with a built-in MPPT charge controller: the BKS-PV4000-24L takes 4000 W of PV and delivers 3000 VA, and the BKS-PV6000-48PL takes 6000 W of PV and delivers 5000 VA, with parallel capability and feed-in to the grid. Both work with lithium and lead-acid batteries, have two AC outputs and a detachable dust cover, and can be monitored over Wi-Fi.

  • Built-in MPPT solar charge controller
  • Wide-range MPPT, 120–500 V
  • Supports lithium and lead-acid batteries
  • Dual AC output
  • Feed-in to grid and parallel operation (5000 VA model)
  • LED display and dry contact
  • Wi-Fi monitoring
  • Detachable dust cover

Applications

Residential solar with battery storageOff-grid homes and small businessesGenerator-assisted sites
ModelRatingParallel capabilitySurge powerPeak efficiencyBattery voltageFloating charge voltageOvercharge protectionMax. PV array powerMax. PV input currentMax. solar / AC / total charge currentNet / gross weight
BKS-PV4000-24L3000 VA / 3000 WNo6000 VA93% @24 V24 VDC27 VDC31 VDC4000 W12 A120 A8.7 kg / 11.0 kg
BKS-PV6000-48PL5000 VA / 5000 WYes10000 VA93% @48 V48 VDC54 VDC61 VDC6000 W18 A80 A9.5 kg / 11.8 kg

Specifications

Common to all models in the series. Specifications are subject to change without notice.

Download datasheet

Input

Phase
1-phase in / 1-phase out
Voltage
230 VAC
Selectable voltage range
170–280 VAC (personal computers); 90–280 VAC (home appliances)
Frequency range
50 / 60 Hz (auto adaptive)
Current
40 A

Output

AC voltage regulation
230 VAC ±5%
Number of outputs
2
Second output on/off
Time setting and battery voltage setting
Transfer time
10 ms
Overload (battery mode)
60 s @102–110% · 10 s @110–130% · 3 s @130–150% · 0.2 s @150%

Battery & solar charger

Battery type
Lithium and lead-acid
Solar charger type
MPPT
MPPT trackers
1
MPPT operating range
120–450 VDC
Max. PV open-circuit voltage
500 VDC

Physical & environment

Dimensions (L×W×H)
510×306×115 mm
Communication
RS485 / RS232 / USB / dry contact
Monitoring
Wi-Fi (optional)
Ingress protection
IP20
Humidity
5–95% (non-condensing)
Operating temperature
−10–50 °C
Storage temperature
−15–60 °C
Max. altitude
4000 m (derating above 1000 m)
Compliance
IEC 61000-6-2, IEC 61000-6-4, IEC 62109-1, IEC 62109-2, IEC 61683

Specifying BKS series hybrid solar inverter?

Share the load, site conditions and timeline, and our team will confirm the right model.

Discuss a requirement
WhatsAppGet help