3 phase transformer-less online ups 10kva-200kva

Number HTT-10KVA~HTT-200KVA

  • DETAILs
  • Features
  • Parameters
Brief:
BAYKEE HTT series UPS, adopt double conversion online type, which is an optimum design for all power failure. This design can effectively protect the loads from surges, meanwhile, ensure output stability, accuracy, reliability power to the loads. This series products adopt all digital control technology, can reach parallel redundancy function, to provide our customer more flexible, future expansion and safety guarantee.

Application:
IDC, financial, computer room, telecom, manufacturer, government project, transportation, medical and commercial use etc..

Features:
Three phase input& output true online
Double DSP+double CPLD all digital accurate operation control
Input power factor up to 0.99, system efficiency>96%
Input THDi<5%, output voltage regulation accuracy < +/-1%
200V-482V wide input range, all loads compatible
Supper Over load capacity and short circuit protection
Digital parallel redundancy tech,multi-parallel, full reliability
Three stage charging, battery each set numbers 30~50 units optional (even) external battery life
Modular design, average maintenance 10 min
EPO function

Model HTT-10KVA HTT-15KVA HTT-20KVA HTT-30KVA HTT-40KVA HTT-60KVA
Capacity 10KVA/10KW 15KVA/15KW 20KVA/20KW 30KVA/30KW 40KVA/40KW 60KVA/60KW
Mains input(AC )            
Phase 3 phase +N+PE
Voltage range 291~492 V(line-line) full load; 200V~291V linearly decrease
Frequency range 35Hz~70Hz
THDi <3% (full linear load)
Power factor 0.995
Bypass range -10%~10% (can customized -10%~-30%, +10%~+20%)
Battery            
Connection type positive series and negative series battery
Rated voltage +/- 240VDC (positive and negative each 20pcs*12V series), can customized
Battery number 40pcs/set (can customize 30~50pcs/set even optional)
Charging current 20% system power (battery capacity)
Output(inverter)            
Output voltage 380VAC 3 phase+N+PE
Voltage regulation   <+/-1%
Phase lock range 50Hz/60Hz+/-5Hz(self frequency 50Hz/60Hz+/-0.01Hz)
Output frequency 50Hz/60Hz+/-0.01(turn into mains frequency if phase locked)
Power factor 1
Crest factor 3:1
THDu THD<2.0% (linear load), THD<3%(non-linear load)
Three phase voltage unbalance degree balance load: 0.5%  100% unbalance load : 1%
Dynamic voltage transient range <3%
Transient Recorery Time 0ms
Three phase voltage deviation mains:0.4;  battery :0.3
Transfer time mains to battery: 0ms;  inverter to bypass: 0ms
Overload capacity 125% for 10min: 150% for 1min; >150% for 200ms (linear load)
System efficiency >96% >95%
Environment indicator            
Noise <65dB @100%load, cooling fan adopt intelligent speed control
Display touch screen LCD+LED
Interface standard: RS232, RS485, dry contacts, SNMP card optional
Operation temperature temperature: -10C ~+40C; humidity 0%~98%; storage temperature -25C~+75C        Altitude(m): <1000, 1000m-2000m above every 100m reduce 1%
IP class IP30( Removable dust filter)
Physical specifications            
Cabinet size (W*D*H) 420*750*880 600*800*1250
Cabinet weight KG 70 70 75 80 85 210
Modules No.(Max)            
NOTES:  subject to change without further notice!
Model HTT-80KVA HTT-100KVA HTT-120KVA HTT-150KVA HTT-200KVA
Capacity 80KVA/80KW 100KVA/100KW 120KVA/120KW 150KVA/150KW 200KVA/200KW
Mains input(AC )          
Phase 3 phase +N+PE
Voltage range 291~492 V(line-line) full load; 200V~291V linearly decrease
Frequency range 35Hz~70Hz
THDi <3% (full linear load)
Power factor 0.995
Bypass range -10%~10% (can customized -10%~-30%, +10%~+20%)
Battery          
Connection type positive series and negative series battery
Rated voltage +/- 240VDC (positive and negative each 20pcs*12V series), can customized
Battery number 40pcs/set (can customize 30~50pcs/set even optional)
Charging current 20% system power (battery capacity)
Output(inverter)          
Output voltage 380VAC 3 phase+N+PE
Voltage regulation   <+/-1%
Phase lock range 50Hz/60Hz+/-5Hz(self frequency 50Hz/60Hz+/-0.01Hz)
Output frequency 50Hz/60Hz+/-0.01(turn into mains frequency if phase locked)
Power factor 1
Crest factor 3:1
THDu THD<2.0% (linear load), THD<3%(non-linear load)
Three phase voltage unbalance degree balance load: 0.5%  100% unbalance load : 1%
Dynamic voltage transient range <3%
Transient Recorery Time 0ms
Three phase voltage deviation mains:0.4;  battery :0.3
Transfer time mains to battery: 0ms;  inverter to bypass: 0ms
Overload capacity 125% for 10min: 150% for 1min; >150% for 200ms (linear load)
System efficiency >95%
Environment indicator          
Noise <65dB @100%load, cooling fan adopt intelligent speed control
Display touch screen LCD+LED
Interface standard: RS232, RS485, dry contacts, SNMP card optional
Operation temperature temperature: -10C ~+40C; humidity 0%~98%; storage temperature -25C~+75C        Altitude(m): <1000, 1000m-2000m above every 100m reduce 1%
IP class IP30( Removable dust filter)
Physical specifications          
Cabinet size (W*D*H) 600*800*1250 600*1100*2000
Cabinet weight KG 230 235 250 415 460
Modules No.(Max)          
NOTES:  subject to change without further notice!